HP StorageWorks HP-UX Kit V3.0B for Enterprise Virtual Array Installation and Configuration Guide (AA-RUHKB-TE, October 2003)
Installing the HP-UX Kit
25HP-UX Kit V3.0B for Enterprise Virtual Array Installation and Configuration Guide
==========================================================
disk 33 8/4.5.0 sdisk CLAIMED DEVICE SEAGATE ST32550W
/dev/dsk/c0t5d0 /dev/rdsk/c0t5d0
disk 3 8/16/5.2.0 sdisk CLAIMED DEVICE TOSHIBA CD-ROM
XM-5401
A
/dev/dsk/c3t2d0 /dev/rdsk/c3t2d0
disk 4 8/16/5.4.0 sdisk CLAIMED DEVICE DEC RZ29B (C) D
D
C
/dev/dsk/c3t4d0 /dev/rdsk/c3t4d0
3. Mount the CD-ROM with the command:
# mount /dev/dsk/c3t2d0 /cdrom
4. Copy the depot file from the CD-ROM to a temporary directory on the host
system.
# cp /cdrom/sssu_v31_hpux.depot /tmp
5. Enter the following command to run the installation program (swinstall):
# swinstall -s /tmp/sssu_v31_hpux.depot
6. The SSSU executable is installed in the following directory:
# /sbin
To execute the Command Line version of the SSSU, enter the following:
# sssu
Checking the HP-UX Driver Version
The FCA device driver for HP-UX A6795 is installed as part of the operating
system. You may wish to check the version to ensure compatibility with the
Enterprise Virtual Array (see the platform-specific release notes for supported
versions).