HP StorageWorks HP-UX connectivity 4.0C for the 3000/5000 Enterprise Virtual Array Release Notes (5697-6586, March 2007)
CAUTION:
Persistent EVA overload may indicate an overloaded configuration, and additional array host port
resources may be required to match the configuration to the actual workload. Consult your HP acc ount
or service representative for help to properly configure the EV A for your newly designed or existing
configuration.
High-availability environment recommendations
In high-availability environments with heavy I/O loads, you may experience I/O timeout conditions. If
I/O time outs occur, HP recommends that you use the pvchange command to increase the IO_timeout
value from the default value of 30 seconds to no more than 60 seconds. Under heavy I/O load
conditions, the increased IO_timeout value allows for long er I/O completion times and LUN access
delays if a c ontroller failover occurs.
NOTE:
Ensure that you have HP ServiceGuard configured properly. For details, see the following website:
h
ttp://docs.hp.com/hpux/ha/i nd ex.html#ServiceG uard
Selecting the management appliance
The menu for selecting the management appliance does not work consistently. Use the following
command to access the user interface for SSSU:
# gsssu
In the com m a nd text box, enter an SSSU comm and ; for example:
select manager ip_address username=xxxx password=xxxx
8