HP StorageWorks Enterprise Virtual Array 3000/5000 updating product software guide (VCS 3.110) (5697-7959, February 2009)

Table 8 System software code segment descriptions
Segment Description
Befor e text Te xt le with information about the new code and upgrade requirements.
Displayed by H P Command View EVA and not sent to the controller.
Information le File stored on the controller's card describing contents of this superle.
OCP image
Firmware for the Operator Controler Panel (LCD entry and display panel) PIC
(8-bit) processor chip.
SDC image
Firmware for System Data Center (Battery, Temperature and Blower manager) PIC
(8-bit) processor chip.
Glue image
Firmware for the GLUE chip FPGA, stored in EEPROM.
CBIC image
Firmware for the CanBus Interface Chip (drive shelf out-of-band communications
chip)PIC(8-bit)processorchip.
Event text le
File enabling
HP Command View EVA to translate binary event data to text. Not
sent to the co
ntroller.
EMU image
Firmware for the Drive Shelf Environmental Monitoring Unit (EMU) module. Stored
on the controllers program card and contains the image for the CTS I/O module.
Boot image
Initial Firmware that the controller's main processor (PPC) runs after reset or
power-on.
Functional
image
EVA rmware that is upgraded and provides support for all EVA functions.
After text Text le with i n formation declaring that upgrade has completed and describing
and post-upgrade requirements. Displayed by HP Command View EVA a nd not
sent to the controller.
8. Click Finish.
The following conrmation message opens.
9. Click OK to upgrade the system software on the controllers. Click Cancel to stop the code load
process and return to the Storage System Properties window.
The upgra de process begins and the Initializ ing rmware code load page opens. See Figure 27.
This page is displayed until the controller code load is complete and the controllers restart. During
this interval both controllers resync and begin operating on the new rmware code. Once the resync
is complete, the controllers begin processing host I/Os.
Additional code within the storage system is now updated, which can take up to 10 minutes to
complete. This includes rmware on the EMU and I/O modules in the disk enclosures. During this
interval, the Storage System Updating Firmware window opens. See Figure 28.
HP StorageWorks Enterprise Virtual Array 3000/5000 updating product software guide (VCS 3.110)
57