HP StorageWorks Enterprise Virtual Array 3000/5000 updating product software guide (VCS 3.110) (5697-7959, February 2009)
Table 7 VCS 3.110 System Software Upgrade Checklist
Step 1. Checking the health of the Enterprise Virtual Array,page47
Time required: 20–30 minutes
HP Command View EVA indicates no hardware problems.
No ha rdware components in the Unmappable Hardware folder.
No critical events entered in the controller event log within the last 48 hours.
Storage s yste
mconfiguration is stable and no configuration changes have been made within the last 48
hours.
Step 2. Disabling ISEE, page 50
Time required: 10–15 minutes
Disabl e ISEE (if used).
Step 3. Clearing storage system passwords,page51
Time required: 10–15 minutes
Clear the OCP password .
D isable password access in H P Command View EVA.
Step 4. Haltin
g all host access to the storage system for an offline upgrade (optional),page53
Time required: Varies by host. Must be performed for each host accessing the storage system
Halt all applications accessing the storage system.
Stop all I/O t
othestoragesystem.
Step 5. Upgrading controller firmware to VCS 3.110,page53
Time required: 25–30 minutes
Things you will need:
• HP StorageWorks EVA 3000/5000 controller media kit.
Upgrade VCS firmware to version 3.110.
Step 6. Upgrading disk drive firmware, page 58
NOTE:
If you are not using HP Command View EVA 6.0, you can only upgrade disk drive firmware offline
to an ungrouped d isk.
Time required: Varies depending on the number of disk drives that must be upgraded. It can take 30 seconds
to 3.5 minutes per drive.
Things you will need:
• Disk drive code bundled image file, which can be downloaded from the following web site:
h
ttp://www
.hp.com/support/evadiskfirmware.
Download t
he disk drive firm ware file.
Up grade th
ediskdrivefirmware.
Step 7. Entering passwords on the HSV controllers, page 63
Time required: 10–15 minutes
Enter the OCP password.
Enab le password access in HP Command View EVA.
Step 8. Resuming storage system operation,page64
Time required: Varies
Restart applications acc essing the storage system if an offline upgrade was performed.
WhenrunningHPContinuousAccessEVA,enablefailsafemodeonallDRgroups.
If you changed any host LUN timeout values, reset them to their original values.
Enable ISEE (if used).
46
Upgrading the Enterprise Virtual Array