HP StorageWorks Enterprise Virtual Array 3000/5000 updating product software guide (VCS 3.110) (5697-7959, February 2009)
Upgrading HP Command View EVA (Optional)
Estimated time to complete: 15–20 minutes
When to per fo
rm: Any time prior to the upgrade
HP Command View EVA 5.x or 6.x is required with VCS 3.110. Check the current version and upgrade
the software if necessar y. If you want to upgrade multiple d isk drives, you must upgrade to HP Command
View EVA 6.0.2 . You can upgrade to version 6.0.2 fr om version 6.0.
For more information on HP Command View EVA, including the HP StorageWorks Command View
EVA installation guide and the release notes, download documentation from the web site listed in
“Required documentation”onpage14.
Upgrading using the typical installation
This procedure is for the typical H P Command View EVA installation. To use the custom installation
procedure, which provides control over which components are installed, see HP StorageWorks Command
View EVA installation guide for instructions.
To install the complete software suite:
1. Close all applications running on the management ser ver.
2. Insert the installation CD into the drive.
3. Browse to the installation CD.
4. Double-click setup.exe to start the installation.
The InstallShield Wizard Welcome window opens.
5. Follow the on-screen instructions to compete the installation.
NOTE:
When SM I-S EVA is installed using the typical installation, a default account for the CIM administrator is
created if an administrator account exists on the management server prior to installation. The default
user name and password is administrator. If an administrator account does not exist on the management
server prior to installation, the default CIM administrator account is not created during installation. You
must add at least one CIM administrator acc ount to CIMOM after completing the installation. See
“Managing users in SMI-S EVA” in the HP Command View EVA installation guide for more information.
A trust relationship between HP Command View EVA and SMI-S EVA is established automatically when
youinstallSMI-SEVA.Asaresult,HPCommandViewEVAacceptsallSMI-SEVAqueries.
Verifying the installation
To verify that the software was installed successfully:
1. Ensure that:
• The software icons for HP Command View EVA
, HP Command View EVAPerf ,and/orHP
Storage System Scripting Utility
appear on the desktop.
If you installed the software suite on an SMA, the HP Command View EVA icon does not appear
on the desktop.
• The software is available from the Start menu (for example, Start > Programs > HP Command
View EV A).
If you installed the software suite on an SM A, the software is not available from the Start menu.
• G o to Add/Remove Programs an d make sure the applicable software components are listed:
• HP StorageWorks Command View EVA software suite
HP StorageWorks Enterprise Virtual Array 3000/5000 updating product software guide (VCS 3.110)
37