HP StorageWorks Enterprise Virtual Array 3000/5000 updating product software guide (VCS 3.110) (5697-7959, February 2009)

Preparing an HP Continuous Access EVA environment for upgrading, page 42
Time required: Varies depending on replication conguration
When to perform: As close as possible to the upgrade
Disable failsafe mode on all DR groups.
Back up all storage sy stem data,page36
Time required: Varies
When to perform: As close as possible to the upgrade
Perform a full
veried backup of all storage system data.
Saving storage system conguration information,page44
Time required: 1015 minutes
When to perform: As close as possible to the upgrade
Things you will need:
HP Storage System Scripting Utility (called the utility). This is included with HP Command View EVA 6.0.
HP StorageWorks Storage System Scripting Utility reference.SeeRequired documentation on page 14.
Capture conguration information using the utility.
Store conguration locally (not on storage system).
Checking current softwar e v ersions
Estimated time to complete: 10–15 minutes
When to per form: Any time prior to the upgrade
When upgrading the system software, it may be necessary to upgrade related management software to
the correct version as required. Use Table 4 to collect version information for your current software. You
must upgrade any software that does not meet the required version.
NOTE:
For complete details on EVA soft ware compatibility, se e the EVA software version compatibility table
and the HP Command View EVA interoperability support table in the HP StorageWorks EVA software
compatibility reference.SeeRequired documentation”onpage14forthelinktothisdocument.