HP StorageWorks Enterprise Virtual Array 3000/5000 updating product software guide (VCS 3.110) (5697-7959, February 2009)

Managing application I/O timeouts for an online upgrade, page 36
Time required: Varies depending on number of applications
When to perform: Any time prior to the upgrade
Determine if any applications have timeouts set to more stringent values than the host LUN timeouts.
Change application timeout parameters to host LUN timeout values.
Upgrading HP Command View EVA (Optional), page 37
Time required: 15 2 0 m i n u t e s
When to perform: Any time prior to the upgrade (upgrading HP Command View EV A is optional).
Things you will need:
HP StorageWorks Command View EVA 5.0 or 6.0 installation media, which is available from the
following web
site:
h
ttp://www.hp.com/support/downloads
Check the HP Command View EVA version; must be at 5.x or 6.x.
Upgrade to version 6.0.2 if necessary.
Upgrading browser a n d Java Runtime Environment (Optional), page 38
Time required: 1020 minutes
When to perform: Any time prior to the upgrade
If you are currently running HP Command View EVA 5.x or 6.x, no action is required.
Upgrade browser if necessary.
Upgrade JRE if necessary.
Upgrading to WEBES 4.5 RU1 (Optional), page 38
Time required: 1020 minutes
When to perform: Any time prior to the upgrade
Things you will need:
WEBES 4.5 and upgrade documentation available from the following web site:
h
ttp://h18023.www1.hp.com/support/svctools/webes/index.html?jumpid=reg_R1002_USEN
UpgradetoWEBES4.5ifnecessary
Upgrading HP Replication Solutions Manager (optional), page 40
Time required: 1020 minutes
When to perform: Any time prior to the upgrade
Things you will need:
HP StorageWorks Replication Solutions Manager 2.1
HP StorageWorks Replication Solutions Manager installation and administrator guide.See
Required documentation”onpage14.
Upgrade t
o HP Replication Solutions Manager 2.1 if installed.
Monitoring storage system stability, page 40
Time required: 2535 minutes
When to perform: 48 hours before the upgrade
V erify there are no critical events entered in the controller event log.
Ensure the storage system conguration is stable and no conguration changes are in progress.
18
Pre-upgrade tasks