HP StorageWorks Enterprise Virtual Array 3000/5000 Release Notes VCS V4.004 (5697-5794, March 2006)
RELEASE NOTES CONTENTS
This docu ment contains the most recent product information for an HP StorageWorks Enterprise Virtual
Array 3000/5000 running VCS v4.004. M uch of the information included here is not documented
elsewh ere, so it is recommended that you read this information thoroughly before installing an d operating
the EVA3000/5000.
The informa
tion in this document was the current at the time of publishing. To ensure you have the most
current in
formation, check the following web sites for a newer edition:
h
ttp://ww
w.hp.com/go/eva5000
http://ww
w.hp.com/go/eva3000
Subscribing to proactive updates
Receive s upp ort alerts (such as Customer Advisories), as well as updates on drivers, software, firmware,
and customer replaceable components, p roactively via email through HP S ubscriber's Choice. Sign
up for Subscriber's Choice at the following URL:
h
ttp://www.hp.com/g o/myadvisory
DESCRIPTION
The VCS v
4.004 system software for the EVA3000/5000 includes resolution to some issues that were
found after the release of v4.001. HP recommends that you upgrade to VCS v4 .004 if yo u are currently
running VCS v4.001. To upgrade to VCS v4.004, a copy of the system software is provided on the
CD-ROM in the HP StorageWorks EVA3000/5000 Series v4.0 Controller Media Kit.
See HP StorageWorks Enterprise Virtual Array 3000/50 00 updating product software guide VCS
v4.004 for instructions on upgrading VCS and associated software applications.
Upgrade paths
The upgrade paths to VCS v4.004 are listed in Table 1. When upgrading to VCS v4.004, the following
conditions must be met:
• Upgrading to VCS v4.004 should only be per formed by HP service-trained personnel. Contact
HP Customer Services for assistance in upg rading the storage system to VCS v4.0 04.
• The storage system must be at VCS 3.028 or VCS v4.001 to upgrade to VCS v4.004.
• Upgrading to VCS v4.004 from VCS 3.028 must be done offline(allhostI/Ohalted).Theonline
upgra de o ption is not supported for these upgrades.
Table 1 VCS v4.004 U p grade Paths
Current VCS
Version
Upgrade Path to VCS v4.004 Upgrade method
supported
v3.028
Upgrade directly to v4.004
Offline
v4.001
Upgrade directly to v4.004
Online
1
or offline
1
The online upgrade procedure requires a 60 second controller resynch during which the storage system is unavailable.
Applications and operating systems must be able to accommodate this interval.
Dow
ngrading
Dow
ngrading from VCS v4.004 to any earlier version of VCS firmware and retaining data on the
sto
rage system is not supported. Contact your HP-authorized service representative for more information
on VCS downgrades.
Enterprise Virtual Array 3000/5000 release notes (VCS v4.004)
1