HP StorageWorks Enterprise Virtual Array 15K RPM Fibre Channel Hard Disk Drive HP07 Firmware Update Release Notes (5697-6453, January 2007)

a. Store the le to a known local directory.
NOTE:
HP recommends that you use the default directory of C:\Program
Files\Hewlett-Packard\Sanworks\CodeLoad.Ifyouuseadifferent
directory, you must enter the complete path when identifying the loc ation of the
rmware le.
b. Double-click the zip le to extract the bundled rmware le. When extracted, the le type is
an executable.
c. Run the executable to extract all of the supported disk drive download les.
2. Open and log into HP Command View EVA.
3. In the Navigation pane, select the array for which you want to update hard disk drive rmware.
The Initialized Storage Systems Properties window opens.
4. Click Code Load.
The Code Load Selection window opens.
5. Select Code Load Disk Drives O n Line.
The Online Disk D rive Code Load - Page 1 window opens.
6. Enter the path to the folder containing the extracted bundled image le.
7. Click Next step.
All disk drives are scanned for conguration information and upgrade eligibility. The results are
displayed in a table when the Online Disk Drive Code Load - Page 2 window opens.
8. Click Next step.
The disk drive rmware upgrade begins. A status page opens, indicating the progress as each
disk drive is upgraded.
NOTE:
The disk drives are upgraded sequentially. Depending upon the I/O load on the storage
system, it can take 30 seconds to 3.5 minutes per drive to upgrade the rmware. The
status is updated at 45–second intervals.
9. When all t
he disk drives have been upgraded, the Code Load Disk Drives On Line - Page 3 window
opens, i
ndicating the drives that have been upgraded successfully. Click Finish.
4