HP StorageWorks 3000/5000 Enterprise Virtual Array updating product software guide (VCS 4.100) (5697-7055, November 2007)
Table 10 VCS 4.100 System Software Upgrade Checklist
Step 1. Check st
orage system health
Command View E
VA ind icates no hardware problems
No hardware co
mponents in the Unmappable H ardware folder
No critical ev
ents entered in the controller event log within the last 48 hours
Storage system configuration is stable and no configuration changes h ave been made within the last 48
hours
Step 2. Disable ISEE and SNMP
Disable ISEE (if used)
Disable SNMP
Step 3. Clear storage system passwords (if used)
Clear OCP password
Disable password access in Command View EVA
Step 4. Halt al
host I/O (optional)
Halt all I/O
Step 5. Upgrade system software
Upgrade VCS sy stem software
Step 6. Upgrade disk drive firmware
Upgrade disk drive firmware
Step 7. En able
storage system passwords ( i f used)
Enter OCP pas
sword
Enable passw
ord access in Command View EVA
Step 8. Resume storage system operation
Enable SNMP (if used)
Enable ISEE (if used)
HP StorageWorks 3000/5000 Enterprise Virtual Array updating product software guide (VCS 4.100)
43