HP StorageWorks 3000/5000 Enterprise Virtual Array updating product software guide (VCS 4.100) (5697-7055, November 2007)
a. When you download the file from the web, the file is downloaded as a zip file. Store the file
to a local directory.
NOTE:
It is recommended that you use the default directory of C:\Program
Files\Hewlett-Packard\Sanworks\CodeLoad. If you use a different
directory, you will have to enter the complete path when identifying the location of
the firmware files.
b. Double-click the zip file to extract the bundled image file. When extracted, the file type is
an executable.
2. Open HP Command View EVA.
3. In the Navigation pane, select the storage system being upgraded.
4. Click Code load.
The Code Load Selection window opens.
Figure 14 Code Load Selection window — disk drives
5. Select Code Load Disk Drives On Line and click Select.
TheCodeLoadDiskDrivesOnLine-Page1windowopens.
34
Upgrading the Enterprise Virtual Array