HP StorageWorks 3000/5000 Enterprise Virtual Array updating product software guide (VCS 4.100) (5697-7055, November 2007)
Figure 10 Valid a ting code segments complete
Table 7 Sys
tem software code segment descriptions
Segment Description
Befor e text Text file with information about the new code and upgrade requirements.
Displayed by HP Command View EVA and not sent to the controller.
Informati
on file
File store
d on the controller's card describing contents of this superfile.
Battery image
F irmware for battery backup system for cached data.
Glue image
Firmware for the GLUE chip FPGA, stored in EEPROM.
CBIC image
Firmware f
or the CanBus Interface Chip (drive shelf out-of-band communications
chip) PIC
(8-bit) processor chip.
Event text file
File enabling HP Command View EVA to translate binary event data to text. Not
sent to the controller.
EMU image
Firmware for the Drive Shelf Environmental Monitoring Unit (EMU) module. Stored
on the controllers program card and contains the im age for the CTS I/O module.
Boot image
Initial
Firmware that the controller's main p rocessor (PPC) runs after reset or
power-o
n.
Functional image
EVA firmware that is upgraded and provides support for all EVA functions.
After text Text file with information declaring that upgrade has completed and describing
and post-upgrade requirements. Displayed by HP Command View EVA and not
sent to the controller.
8. Click Finish.
The following confirmation message opens.
HP StorageWorks 3000/5000 Enterprise Virtual Array updating product software guide (VCS 4.100)
31