Check the storage system event logs.
1. Run HP Command View EVA and log in.
2. Select the storage system whose logs you want to view.
3. Click View events to view the event logs that can be displayed.
If none of the above recommendations resolves the problem, contact your HP-authorized service
representative for help.
Solving problems with multiple resynchronizations (Step 10)
During the upgrade process, both controllers perform a resynchronization simultaneously. This invokes
a fast restart of the controllers — bypassing execution of lengthy hardware diagnostics. This fast restart
allows the controllers to complete the resynchronization sequence before the host timeout period
elapses and the host becomes aware that the storage system is unavailable.
If an event occurs that causes a second resynchronization while the firmware upgrade resynchronization
is still in progress, the controller will terminate with a code of 0b 08 01 00. The following events
cause the controller to resysnchronize automatically:
Initialization of the storage system
Setting debug flags through the command line interface or OCP
Occurrence of a disk group hardware problem on a Vraid1 virtual disk, or the return of a disk
during this condition
Bad Block Replacement (BBR) performed on a disk
Memory allocation failure or other errors
Every effort should be made to ensure none of these events occur during the upgrade process. If
controller termination occurs due to multiple resynchronizations, contact your HP-authorized service
representative for assistance.
HP StorageWorks 3000/5000 Enterprise Virtual Array updating product software guide (VCS
3.110) 65