HP StorageWorks 3000/5000 Enterprise Virtual Array updating product software guide (VCS 3.110) (5697-8108, March 2009)
3 Upgrading the Enterprise Virtual Array
The following steps guide you through the process of upgrading the system software. Ensure that you
follow them carefully and in the specified order. Table 5 on page 37 provides a checklist so you can
track your progress as you perform the upgrade. Make sure you have all the items indicated before
beginning the upgrade.
Upgrading remotely versus locally
You can perform the upgrade from a local server or from a remote server. Some advantages to
performing the upgrade locally include:
• Enables you to view the various status indicators on the storage system hardware to ensure
everything is working properly.
• Provides access to the controller operator control panel (OCP) to clear storage system passwords
and to monitor messages.
• Reduces the amount of time involved during file transfers. The shorter distance over the network
the code files must travel, the faster the transfer will occur.
Solving upgrade problems
If you experience any problems when performing the VCS upgrade procedure, see
“Troubleshooting” on page 57 for assistance. If you are still unable to resolve the problem, contact
your HP-authorized service representative for assistance.
Table 5 VCS 3.110 System Software Upgrade Checklist
Step 1. Checking the health of the Enterprise Virtual Array, page 38
Time required: 20–30 minutes
– HP Command View EVA indicates no hardware problems.
– No hardware components in the Unmappable Hardware folder.
– No critical events entered in the controller event log within the last 48 hours.
– Storage system configuration is stable and no configuration changes have been made within the last 48
hours.
Step 2. Disabling Remote Support Software, page 41
Time required: 10–15 minutes
– Disable Remote Support Software (if used).
Step 3. Clearing storage system passwords, page 42
Time required: 10–15 minutes
– Clear the OCP password.
– Disable password access in HP Command View EVA.
HP StorageWorks 3000/5000 Enterprise Virtual Array updating product software guide (VCS
3.110) 37