HP StorageWorks 3000/5000 Enterprise Virtual Array release notes (VCS 3.110) (5697-8109, March 2009)
snapshot or snapclone. The impact of creating one snapshot may be tolerable and may not require
this action. However, creation of multiple snapshots of the same virtual disk requires this action.
Avoiding controller termination during snapshot and snapclone unsharing
Under certain instances, a controller termination is seen when snapshots and snapclones unsharing
is in progress, and also, at the same time a full copy is in progress. To avoid a controller termination,
snapclones should not be created of DR Group members while a full copy is in progress.
McData Intrepid 1000 Director switch and EVA
The McData Intrepid 1000 Director switch is not supported when directly connected to the EVA. It is
supported when the EVA is connected to another Director switch or an Edge switch in the fabric while
the Intrepid 1000 Director switch is also in the fabric.
VCS 3.xxx and McData 4400/4700 switches
An EVA3000/5000 that is running VCS 3.xxx may experience login problems on port 0 of McData
ES4400 or ES4700 switches. To resolve this problem, use any port other than port 0 for the EVA
connection.
HP StorageWorks 3000/5000 Enterprise Virtual Array release notes (VCS 3.110) 9