HP StorageWorks 3000/5000 Enterprise Virtual Array Connectivty 3.1A for Sun Solaris Release Notes (5697-6384, June 2007)

Codeload usage
When a maximally con gured system is running at maximum load, Secure Path timing constraints make
codeload functionality ineffective. The system may time-out before codeload is complete. Therefore, you
should p erform
VCS upgrades at an off-peak time.
SSSU
Changing comments on a disk enclosure
Use Command View EVA to change comments on a disk enclosure. If you try to change a disk enclosure
comment using SSSU, the following error message appears:
Error: Invalid Operation
Changing the name of a disk enclosure
Changing the name of a disk enclosure is not supported with SSSU or with Command View EVA . If you
try to change a disk enclosure name using SSSU, the following error message appears:
Error: Invalid Operation
HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity 3.1A for Sun Solaris re lease notes