HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity for OpenVMS installation and reference guide (5697-7043, November 2007)
Updating the AlphaServer console code, Integrity Server
console code, and Fibre Channel FCA firmware
The firmware update procedure varies for the different server types. To update firmware , follow the
procedure desc
ribed in the installation instructions that accompany the firmware images.
Veri fying Fibre Channel adapter software installation
A supported FCA should already b e installed in the host server. The procedure to verify that the console
recognizes the installed FCA varies for the different server types. Follow the procedure described in the
installation instructions that accompany the firmware images.
HP StorageWor
ks Command View EVA and HP StorageWorks
Storage Sy st
em Scripting Utility
The Storage S
ystem Scripting Utility (SSSU) is delivered as part of HP StorageWorks Command View
EVA. The SSSU
is a command line interface you can use to issue commands directly to the controller.
The latest version of the SSSU is available on the software downloads website:
h
ttp://www.hp.com/support/downloads
Under Stora
ge, click Storage Software and then select HP StorageWorks Command View EVA Soft ware
under Stora
ge Device Management Software. Select the version of HP StorageWorks Command View
EVA Media Kit you want to download.
Console LUN ID and OS unit ID
TheHPCommandViewEVAsoftwaredisplaysafield for the Console LUN ID on the Initialized Storage
System Properties page.
It is very important that you set the Console LUN ID to a number other than zero. If the Console LUN ID is
not set or is set to zero, the OpenVMS host will not see the controller pair. After the Console LUN ID is set
for a controller pair, you do not have to concern yourself with it until another controller pair is introduced
in the SAN (see Table 2 for an example of how the Console LUN ID displays).
The HP Command View EVA software displays a field for the OS Unit ID. This field is required for
OpenVMS host machines.
This is an ID field that can be set on the virtual disk properties page. The default setting is 0, which
disables the ID field. To enable the ID field, you must specify a value bet ween 1 and 32767.
CAUTION:
It is possible to enter a duplicate Console LUN ID or OS Unit ID number. You must ensure that the
Console LUN ID and OS Unit ID number you enter does not duplicate one already in use. A duplicate
Console LUN ID or OS Unit I D number could allow the OpenVMS hosts to corrupt data through confusion
about LUN identity as well as have the host not see the contr ollers .
Table 2 Comparing console LUN to OS unit ID
ID type
System Display
Console LUN ID set to 100 $1$GGA100:
OS UNIT ID set to 50
$1$DGA50:
10
Host connectivity