HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity for HP-UX installation and reference guide (5697-7039, November 2007)

NOTE:
If it is the rst time the virtual disk LUN is presented to the host, you may need to restart the
host to rescan for newly presented virtual disks.
Sample output from a rescan
Thefollowingisasampleoutputfromanioscan command:# ioscan -fnCdisk
Class
I H/W Patch
Driver
S/W
State
H/W Type
Description
================================================================
disk
00/0/1/0/.1.1
sdisk
CLAIMED DEVICE
HP DVD-ROM 305
/dev/dsk/c0tld0 /dev/rdsk/c0t1d0
disk
10/0/2/0.6.0
sdisk
CLAIMED DEVICE
SEGATE ST318404LC
/dev/dsk/c1t6d0 /dev/rdsk/c1t6d0
disk
20/0/2/1.6.0
sdisk
CLAIMED DEVICE
SEGATE ST318404LC
/dev/dsk/c2t6d0 /dev/rdsk/c2t6d0
disk
7 255/0.0.1
sdisk
CLAIMED DEVICE
SEGATE ST318404LC
/0x6005008B4000145020000B00000080000
/dev/dsk/c32t0d /dev/rdsk/c32t0d1
disk
28 255/0.0.2
sdisk
CLAIMED DEVICE
HSV110(C)COMPAQ LUN
0x6005008B4000145020000B000000D0000
/dev/dsk/c32t0d2 /dev/rdsk/c32t0d2
disk
29 255/0.0.3
sdisk
CLAIMED DEVICE
HSV110(C)COMPAQ LUN
0x6005008B4000145020000B00000120000
/dev/dsk/c32t0d3 /dev/rdsk/c32t0d3
disk
30 255/0.0.4
sdisk
CLAIMED DEVICE
HSV110(C)COMPAQ LUN
0x6005008B4000145020000B00000150000
/dev/dsk/c32t0d4 /dev/rdsk/c32t0d4
disk
31255/0.0.5
sdisk
CLAIMED DEVICE
HSV110(C)COMPAQ LUN
0x6005008B4000145020000B00000210000
TBD
View the ioscan and insf man pages for more information on using these commands.
If you are unable to access the virtual disk, check the following:
Verify all cabling to the switch, Enterprise Virtual Array, and host.
Verify all rmware levels (check the associated Enterprise Virtual Array release notes for details).
Ensure tha t you are running a supported version of the host operating system (see the host-specic
release notes).
Ensure that HP-UX is selected as the operating system for the virtual disk in the HP Command
View EVA.
12
Testing connections to the EVA3000/5000