HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity 4.1A for Tru64 UNIX release notes (5697-7036, November 2007)

Enhancements
This release includes the following new features:
This release includes support for EVA3000/5000 controller software VCS 4.100. For details about
VCS 4.100, see H
P StorageWorks 3000/5000 Enterprise Virtual Array release notes (VCS 4.100).
NOTE:
You must have V CS 3.02 8 installed before upgrading to VCS 4.00x or later. HP recommends that
you do a full system backup before an HP service representative performs the migrating procedure.
Prerequisites
Multiple-path support
Tru64 UNIX operating software includes multipath support. No additional software is required to achieve
high-availability, multipath capability.
For more information about multipath options, see the HP multipath website:
h
ttp://h18006.www1.hp.com/products/sanworks/mul tipathoptions/ index.html
Single-path support
Tru64 UNIX servers require a single FC A to support single-path mode.
NOTE:
Do not use single-path mode in mission-critical environments.
VCS 3.028 to VCS 4.100 migration
The Active/Active failover feature in VCS 4.00x impacts host congurations. Contact your HP service
representative to congure your system and perform the m igration procedure.
EVA stor age system
These release notes contain the latest product information for operating the EVA3000/5000 on a
Tru64 UNIX system.
EVA best practices
The EVA 3000/5000 is designed to work in a wide range of congurations; however, some of
the cong u ration options can inuence performance, c apacity, or availability. With the necessary
information about EVA conguration o ptions, you can m a nag e the c on guration to optimize its at tributes
for a specic application. These conguration options include:
Number of disk groups
Type of disk group
Type and number of disks in a disk group
Vraid levels (0, 1, and 5)
Disk failure protection level (none, single, and double)
Cache settings
4