HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity 4.1A for Sun Solaris release notes (5697-7035, November 2007)
Prerequisites
Multipathing support
A Sun Solaris system with EVA3000/5000 storage requires the installation of either Sun Solaris
MPxIO/Multipathing or VERITAS VxVM/DMP multipathing software on each host to achieve
high-availability, multipath capabilit y. Sun Solaris MPxIO/Multipathing and VERITAS VxVM/DMP
multipathing software require at least one FCA connected to both controllers. VERITAS VxVM/DM P c an
require installation of an array support library in order to recognize the arrays. For more information, see
the HP StorageWorks MPxIO for Sun Solaris ap plication notes or the H P StorageWorks EVA3000/5000
Enterprise Virtual Array hardware configuration guide.
VCS 3.028 to VCS 4.00x migration
The Active/Active failover feature in VCS 4.00x impacts host confi gurations. Contact your HP service
representative to confi gure your system and perform the m igration procedure.
Compatibility/interoperability
This release p rovides full support for all previous EVA controller soft ware used in an existing SA N
configuration.
Storage system attachments
Table 3 l
ists the supported Solaris storage system attachm ents.
Table 3 S
upported platforms
Platform
Model number
Sun Fire
(SPARC)
280R V12
0 V 210 V 215 V 24 0
V245 V25
0V440V445V480
V490 V8
80 V890, V1280
4800 48
10 6800 12K 15K
E2900 E
6900 E20K E25K
Sun Enterprise
(SPARC)
E220R E420R E250 E450
E3000 E3500 E4000 E4500
E5000 E5500 E6000 E6500
E10000
HP ProLiant:
nl
DL145 DL385 DL585 BL25p
BL35p BL45p BL460c BL465c
BL480c BL685c DL145 G2,
DL385 G2, DL585 G2
x86/x64 Servers
nl
(Solaris 10 only)
Sun Fire:
nl
V40z x4100 x4200 x4600,
x8400 x84 20 x8440
SPARC
1,
Enterprise
(Sun, FSC
2
)Solaris
10 only
M4000 M5000 M8000
M9000 T1000 T2000
FSC PRIMEPOWER
(SPARC )
PW25
0PW450PW650
PW8
50 PW900 PW1500
PW2
500
1
HP
supports these servers the same way as Sun servers whether they are sold by Sun or FSC.
2
Fujitsu Siemens Computers
6