HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity 4.1A for OpenVMS release notes (5697-7034, November 2007)
NOTE:
You must have VCS 3.028 installed before upgr ading to VCS 4.00x or later. HP recommends that
you do a full system backup before an HP service representative performs the migrating procedure.
Prerequisites
Multiple-path support
OpenVMS operating software includes multipath support. No additional software is required to achieve
high-availability, multipath capability.
For more information about multipath options, see the HP multipath website:
h
ttp://h18006.www1.hp.com/products/sanworks/multipathoptions /index.html
Single-path support
OpenVMS servers require a single FCA to support single-path m ode.
NOTE:
Do not use single-path mode in mission-critical environments.
VCS 3.028 to
VCS 4.100 migration
The Active/
Active failover feature in VCS 4.00x impacts host configurations. Contact your HP service
representa
tive to configure your system and perform the migration procedure.
EVA storage s ystem
These release notes contain the latest product information for operating the EVA3000/5000 on an
OpenVMS system.
EVA best practices
The EVA3000/5000 is designed to work in a wide range of configurations; however, some of
the configuration options can influence performance, c apacity, or availability. With the necessary
information about EVA configuration options, you can manage the configuration to optimize its attributes
for a specific application. These configuration options include:
• Number of disk groups
• Type of d
isk group
• Type and number of disks in a disk group
• Vraid levels (0, 1, and 5)
• Disk fa
ilure protection level (none, single, and double)
• Cache set tings
For m ore information on the configuration options, see the HP StorageWorks Enterprise Virtual Array
configuration best practices - white pap er on the HP s upport website:
h
ttp://h20000.www2.hp.com/bc/docs/suppor t/SupportManual/lpg29448/lpg29448.pdf