HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity 3.
Legal and notice information © Copyright 2007 Hewlett-Packard Development Company, L.P.
Version: 3.110 Description This document describes Linux operating system connectivity for HP StorageWorks 3000/5000 Enterprise Virtual Array (EVA3000/5000) controller software. A complete library of EVA3000/5000 documentation is available on the HP support website: http://www.hp.com/support/manuals Under storage, click Disk Storage Systems and then select either HP StorageWorks 3000 Enterprise Virtual Array or HP StorageWorks 5000 Enterprise Virtual Array under EVA Disk Arrays.
Platform IA64 Red Hat EL [ES/AS/WS] X86, X86_64 Red Hat EL [AS/ES/WS] IA64 Red Hat EL [AS/ES/WS] 4 OS version Kernel FCA (HBA) 3 U7 3 U8 2.4.21-40.EL 2.4.21-47.EL A6826A A7538A Adapter BIOS/EFI Adapter driver 1.49 7.07.03p4 1.70a3 7.3.4 FCA2214 FCA2214DC HP: Q-Mezzanine HP: FC Adapter HP: Q-Balcony HP: Q-HPBALCF105 1.45 8.01.06.01 QMH2462 1.26 Multi Boot 1.57 8.01.06.01 FC1143 (PCI-X 2.0) FC1243 (PCI-X 2.0) FC1142SR (PCI-e) FC1242SR (PCI-e) 1.16 Multi Boot 1.41 8.01.06.
Platform OS version Kernel FCA (HBA) X86, X86_64 SLES [ES/SS] 8 SP3 8 SP4 2.4.21-273 2.4.21-278 FCA2214 FCA2214DC HP: Q-Mezzanine HP: FC Adapter HP: Q-Balcony HP: Q-HPBALCF105 IA64 SLES [ES/SS] 8 SP3 8 SP4 2.4.21-273 2.4.21-278 Adapter BIOS/EFI Adapter driver 1.45 7.07.03p4 QHMH2462 1.26/Multi Boot 1.57 7.07.03p4 FC1143 (PCI-X 2.0) FC1243 (PCI-X 2.0) FC1142SR (PCI-e) FC1242SR (PCI-e) 1.16 Multi Boot 1.41 7.07.03p4 Emulex FC mezzanine 1.71a0 7.3.
Platform OS version Kernel FCA (HBA) X86, X86_64 SLES [ES] 9 SP2 9 SP3 2.6.5-7.191 2.6.5-7.244 FCA2214 FCA2214DC HP: Q-Mezzanine HP: FC Adapter HP: Q-Balcony HP: Q-HPBALCF105 IA64 SLES [ES] 6 9 SP2 9 SP3 2.6.5-7.191 2.6.5-7.244 Adapter BIOS/EFI Adapter driver 1.45 8.01.06.01 QMH2462 1.26 Multi Boot 1.57 8.01.06.01 FC1143 (PCI-X 2.0) FC1243 (PCI-X 2.0) FC1142SR (PCI-e) FC1242SR (PCI-e) 1.16 Multi Boot 1.41 8.01.06.01 Emulex FC mezzanine 1.71a3 8.0.16.
Platform X86, X86_64 SLES OS version Kernel FCA (HBA) Adapter BIOS/EFI Adapter driver 10 2.6.16.21-0.8 FCA2214 FCA2214DC HP: Q-Mezzanine HP: FC Adapter HP: Q-Balcony HP: Q-HPBALCF105 1.45 8.01.06.01 QMH2462 1.26 Multi Boot 1.57 8.01.06.01 FC1143 (PCI-X 2.0) FC1243 (PCI-X 2.0) FC1142SR (PCI-e) FC1242SR (PCI-e) 1.16 Multi Boot 1.41 8.01.06.01 Emulex FC mezzanine 1.71a0 8.1.6.6 Emulex FC mezzanine for C-series blades 6.00a2 8.1.6.6 FC2142SR (PCI-e) FC2242SR (PCI-e) 1.71a0 8.1.6.
• HP StorageWorks EVA4000/6000/8000 • XP Series • Support is provided for updated kernels (see Table 1 Prerequisites Multiple-path support Linux with EVA storage requires the installation of StorageWorks Secure Path or Multipathing software to achieve high-availability, multipath capability. For detailed multipathing information, refer to the HP StorageWorks using the QLogic 7.xx.xx and 8.xx.xx driver for single-path or multi-path failover mode on Linux systems application note.
Codeload usage When a maximally configured system is running at maximum load, codeload functionality is not effective due to Secure Path timing constraints. The system may time-out before codeload is complete. Therefore, you should always perform VCS upgrades at an off-peak time. SSSU Changing comments on a disk enclosure Use HP Command View EVA to change comments on a disk enclosure.