HP StorageWorks 3000/5000 Enterprise Virtual Array Connectivity 3.1A for HP-UX Release Notes (5697-6380, June 2007)

CAUTION:
Persistent EVA overload may indicate an overloaded conguration and additional array host port
resources may be required to match the conguration to the actual workload. Consult your local HP
account or service representative for help to properly congure the EVA for your newly designed or
existing conguration.
High-availability environment recommendations
In high-availability environments, under heavy I/O loads, you may experience I/O time-out conditions. If
I/O timeouts occur, HP recommends that you use the pvchange com m and to increase the IO_tim eout
value from the default value of 30 seconds to no m ore than 60 seconds. Under heavy I/O load
conditions, the increased IO_timeout value allows for longer I/O completion times and for LUN access
delays if a controller failover condition occurs.
NOTE:
Ensure that you have HP MC/ServiceGuard conguredproperly.Fordetails,gotothefollowingwebsite:
h
ttp://docs.hp.com/hpux/ha/index.html#ServiceGuard.
Selecting
the management appliance
The drop-d
own menu for selecting the management appliance or cells does not work consistently. Use the
following
command to access the GUI for the SSSU:
# gsssu
In the command text box, enter the SSSU command you want to perform. For example:
select man
ager ip_address username=xxxx password=xxxx
HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity 3.1A for HP-UX release notes