HP StorageWorks Enterprise Modular Library E-Series User Guide (AH876-96001, September 2007)

Problem
Corrective action
The library or tape drives are
not d etected by the Interface
Manager card or Command View
TL software.
Check cable connections.
Check the cabling. Make sure that all radial bends a re greater
than 5 cm (2 inches) in diameter.
Make sure that the tape drives and librar y are powered on and
can be seen by the OCP and hosts.
Check that the FAULT LED on the tape drives are off.
Check the log les for network problems.
Make sure that the interface controllers are powered on and ready.
During initialization, the library
robot stops moving and the OCP
status bar is red.
Use Command View TL or L&TT to generate a support ticket and
check the event log.
Check the last entry in the critical error log on the O CP. Use the
followi
ng errors as examples in correcting the problem:
0100: M o
dule # does not have RLP(2)
Check po
wer to the module number. Refer to the checks listed
previo
usly under “The library does not power on.
5501: F
ailed target calibration for MRC: X, X, X
Make su
re that nothing is obstructing the bar co de reader.
Make su
re that the magazine is i nstalled and seated p roperly.
Check
for defective magazine target markings.
0000: End of Text
Open the library door and check the picker for a tape cartridge. If so,
remove the tape cartridge and place it i nto an empt y slot. Close the
library door to start an inventory.
Opcode: 0514 (Robot needs to be reset)
The library can fail to initialize if a tape is located on t he oor. If
unable to use Command View TL or Telnet, disconnect the network
connection and reconnect.
One or more tape drives fail during
startup.
Check power supply indicator for power to the tape drive.
Check that the tape drive is properly cabled and ready.
Check the link indicators on the interface controllers for a valid link
to the tape drives.
Check whether the FAULT indicator is lit on the back of the tape
drive. If so, diagnose the problem.
Makesurethetapedrivehastheappropriatermware.
The OCP disp lays a yellow warning
and the Status > Health Summary >
Interface Manager screen indicates
the Interface Manager card is
initializing.
Check cable connections.
Check Interface Manager card a nd interface controller
congurations.
If problem persists:
Reset the interface controller.
Power cycle the library.
Reset the default conguration on the interface controller.
70
Maintaining the librar y