HP StorageWorks Enterprise Modular Library E-Series User Guide (AH876-96001, September 2007)
11667
FAULT
1
2 3 4
Figure 40 Indicators o n an LTO4 tape drive
Table 14 Indicators on an LTO4 tape drive
Index
No.
Control/indicator
Function
1
FAULT LED
When lit (yellow), indicates that initialization is in
progress, the library robotics controller software has
detected a failure that requires the replacement of the
tape drive assembly, or a hot swap can occur.
When not lit, indicates normal operation.
2
ID Beacon.
3
FC A
When lit (green), indicates link activity on FC port A.
4
FC B
When lit (green), indicates link activity on FC port B.
Switch for the internal net work
60
Using the library