HP StorageWorks Enterprise Modular Library E-Series user guide (AH876-96001, October 2007)

4. Plug the power cord into the power supply.
5. If the power to the library was previously turned off, turn on the power to the library.
Power supply in
the card cage expansion module
Part number
3 7 5816-001 or 409858-001
Location
Bottom of the card cage expansion module
Characteristics
Hot-swappable and redundant
3U x 8HP size with two LEDs
Function
Provides100240VAC,3A,4763Hz,tothecardcage
expansion module
Illustration
10471
Required tools
#2 Philli
ps screwdriver
Removing a power supply from the card cage expansion module
1. Identify the power supply to be replaced. The FAULT LED light might be lit (see
Power supply in the card cage expansion module on page 63).
2. Loosen the two captive screws. One screw is in the black ejector handle and the other screw is
located on the top-right corner of the power supply back panel. Use a #2 Phillips screwdriver.
WARNING!
The power supply might be hot.
3. Push the black ejector handle to the left.
4. Pull the ejector handle to remove the power supply from the library.
Enterprise Modular Library E-Series