HP StorageWorks Enterprise Modular Library E-Series user guide (AH876-96001, October 2007)
HP StorageWorks
Interface Manager card
Part Number
342213-001 or 393531 -001
Location
Bottom slot in t
he base-module card cage
Characteristics
Contains six Ethernet connections to the library robotics controller,
four interface controllers, and the SAN; two 3-pin serial ports;
status, activity, and error LEDs
Function
Manages the interface controllers in order to monitor and
manage the library
Illustratio
n
10463
Required tools
• #1 Phillips screwdriver
Removing t
he Interface Manager card
1. Use your backup software to stop all library activity and make sure the picker is empty.
2. Turn off the power to the library.
3. Identif
y the Interface Manager card. It is located in the bottom slot in the card cage in the base
module.
4. Label the cables or write a note that shows the locations of all the cables plugg ed into the Interface
Manager
card to make it easier to reconnect them later.
5. Unplug
all cables from the Interface Manager card.
6. Loosen
the captive screws in the ejector handles at both ends of the Interface Manager card. Use a
#1 Phillips screwdriver.
7. Push the ejector handles to the outside.
8. Pull t
he ejector handles to remove the Interface M anager card from the library.
Enterprise Modular Library E-Series
83