HP StorageWorks EML E-Series Tape Library Internal Network Kit Installation and Replacement Instructions (AJ001-96001, September 2007)

Installing the switch
9 Attach the brackets to the new switch
11578
Use a #2 Philli
ps screwdriver .
10 Plug the p ower cord into the back
of the sw itch
11579
11 Install th
eclipnutsintherack
If you are replacing the switch, skip this step because the clip nuts will
already be installed.
11580
41
42
40
Install the clip nuts at the 41C position in the rack.
12 Insert the switch into the library and
attach it to th e rack
11581
Route the power cord so that it can reach to the power strip on the left
side of the cabinet. Use a #2 Phillips screwdriver to tighten the screws.
13 Plug the cables into the switch
11574
NOTE:
If an LTO
4 tape drive is not already installed, follow the
instruc
tions on the tape drive installation poster to install it.
If the switch was previously installed, use the labels on the cables or
the note that you wrote to reconnect the cables exactly as they were
connected before. If you are installing the switch for the rst time, plug
an Ethernet cable from the MGMT port on each LTO4 tape drive to a
numbered port on the switch. HP recommends th at you connect the
tape drives in order starting with connecting the top tape drive to port
1. LTO3 tape drives do not connect to this switch.
Page 3