HP StorageWorks EML E-Series e2400 FC 4G Interface Controller Replacement Instructions (December 2005)

10
Power on the library.
a. Set the library power switch at the upper
right corner to the ON position.
b. Observe that all power indicators on the
power supplies show that power was
restored.
c. Verify that the library robotics controller
card ACTIVE indicator is lit.
11
Verify that the power LED and the Fibre Link LEDs
on the interface controller are solid green. The
link LEDs indicate a good connection.
12
To prepare the IC
for configuration,
you must reset the IC
TWICE. To reset the
IC, insert a paper
clip into the Reset hole. After
resetting the IC, wait three minutes for the IC to reset,
then reset it again. Wait another three minutes for
the IC to reset, then use HP StorageWorks
Command View TL to configure the IC.
Caution: If you do not allow sufficient time
for the IC to reset before resetting it again,
the Interface Manager will not recognize
the IC.
13
Close the back
doors of the library.
Getting help
HP product information:
http://www.hp.com/products/tapestorage
HP technical support and phone numbers:
http://www.hp.com/support
HP StorageWorks Library and Tape Tools
(L&TT) diagnostic software:
http://www.hp.com/support/tapetools
Interface Manager and HP StorageWorks
Command View TL:
http://www.hp.com/support/cvtl