HP StorageWorks EML E-Series Power Supply Base Unit Replacement Instructions (May 2005)
Replacement
Remove the power supply by pulling it out by the
handle.
56
7 8
Remove the power supply bracket by removing
the two 6-32 x 1/4 Torx-head screws securing it
to the power supply.
Attach the power supply bracket
to the replacement power supply
using the two 6-32 x 1/4 Torx-head screws.
Slide the replacement power supply into the spot
vacated by the removed power supply and secure
with the two 6-32 x 3/8 screws previously removed.
Removal
3
Locate the faulty power supply. Power supplies
are located to the left of the drive bays. You will
need a Torx T-15 screwdriver to remove and replace
this power supply.
4
To remove a power
supply from the base
module, make sure that
you have removed the
power supply power
cord from the AC power
strip. Remove the two 6-
32 x 3/8 Torx-head screws securing the power
supply to the base module with a Torx T-15
screwdriver.
Warning: The power supply might be
hot.
Primary
power supply
Redundant
power supply