FW 07.00.00/HAFM SW 08.06.00 McDATA E/OS SNMP Support Manual (620-000131-620, April 2005)
B
Event Group
B-47
FC Management MIB
connUnitLinkAgentPortY
Syntax INTEGER
Access read-only
Status mandatory
Description The IP port number for the agent. This is provided in case the agent is
at a non-standard SNMP port.
Sequence
::= { connUnitLinkEntry 11 }
connUnitLinkUnitTypeY
Syntax FcUnitType
Access read-only
Status mandatory
Description Type of the FC connectivity unit as defined in connUnitType.
Sequence
::= { connUnitLinkEntry 12 }
connUnitLinkConnIdY
Syntax OCTET STRING (SIZE(3))
Access read-only
Status mandatory
Description This is the Fibre Channel ID of this port. If the connectivity unit is a
switch, this is expected to be a Big Endian value of 24 bits. If this is
loop, then it is the ALPA that is connected. If this is an eport, then it
will only contain the domain ID. If not any of those, unknown or
cascaded loop, return all bits set to 1.
Sequence
::= { connUnitLinkEntry 13 }
connUnitLinkCurrIndex
Syntax INTEGER
Access read-only
Status mandatory
Description The last used link index.