FW 07.00.00/HAFM SW 08.06.00 McDATA E/OS SNMP Support Manual (620-000131-620, April 2005)
A
FA MIB
A-7
Fibre Alliance MIB
Status current
Description The number of connectivity units present on this system. May be a
count of the boards in a chassis or the number of full boxes in a rack.
Sequence
::= { fcMgmtConfig 1 }
fcConnURL
Syntax DisplayString
Max-Access read-only
Status current
Description The top-level URL of the system. If it does not exist the value is an
empty string. The URL format is implementation dependent and can
have keywords embedded that are preceeded by a percent sign (eg,
%USER).
The following are the defined keywords that will be recognized and
replaced with data during a launch:
A management application will read this object from the MIB,
provide values for any of the keywords listed above that are present
in the string, and then use the URL to invoke or launch the program
referenced.
Sequence
::= { fcMgmtConfig 2 }
Connectivity table The connectivity table contains general information on the system's
connectivity units.
fcConnUnitTable
Syntax SEQUENCE OF FcConnUnitEntry
Max-Access not-accessible
Status current
USER - replace with username
PASSWORD - replace with password
GLOBALID - replace with globalid
SERIALNO - replace with serial number