FW 07.00.00/HAFM SW 08.06.00 McDATA E/OS SNMP Support Manual (620-000131-620, April 2005)

2
Fibre Alliance MIB
2-105
McDATA SNMP Support
NOTE: Each implementation may chose not to support SNMP Set operations
for any or all of these values. For Sets specifying varbinds for instances of this
object and values not supported by a given implementation, the agent will
return the SNMP WrongValue PDU error code.
The values are defined as follow: unknown (1), invalid (2),
resetConnUnitColdStart (3), resetConnUnitWarmStart (4),
offlineConnUnit (5), onlineConnUnit (6).
FcConnUnitContact
Type SnmpAdminString
Product Mapping Contact information for this connectivity unit.
Writable and persistent across IPL.
Access R/W
Description Contact information for this connectivity unit. The contact
information is intended to facilitate contacting someone in case of
problems, questions, etc. (e.g., the help desk internal to a company).
FcConnUnitLocation
Type SnmpAdminString
Product Mapping The physical location of the switch.
Writable and persistent across IPL.
Access R/W
Description Location information for this connectivity unit.
FcConnUnitEventFilter
Type FcEventSeverity
Writable and it’s set to the Default value of info(8) after IPL.
Access R/W
This value defines the event severity that will be logged by this
connectivity unit. All events of severity less than or equal to
fcConnUnitEventFilter are logged in the fcConnUnitEventTable.