HP StorageWorks Clustered Gateway 3.6.0 Windows Storage Server Edition Event Notification Guide (5697-7151, January 2008)

Chapter 3: Event Messages 35
17001 Singleton cluster unable to take control of SAN, because the cluster that
includes NN.NN.NN.NN currently controls the SAN. Possibly this server
has not been added to the cluster or has been deleted from the cluster, or
possibly a networking failure or misconfiguration has partitioned this server
from the servers that control the SAN.
Action. Check the cluster configuration and add the server if it is not
currently a member. Also check the network to ensure that the server can
communicate with the rest of the cluster.
17002 Singleton cluster takes control of SAN failure resolved.
Action. None. Alert 17001 is resolved.
17003 This cluster unable to take control of SAN, because another cluster that
includes NN.NN.NN.NN currently controls the SAN. Possibly a networking
failure or misconfiguration has partitioned these servers from the servers
that control the SAN, or possibly this cluster has been misconfigured to
share membership partitions with another cluster.
Action. Check the cluster configuration and add the server if it is not
currently a member. If your site has more than one cluster, use mprepair to
make sure that this server is using the correct set of membership partitions.
17004 This cluster takes control of SAN failure resolved.
Action. None. Alert 17003 is resolved.
17005 This cluster is unable to take control of SAN, because the servers are unable
to perform fencing operations, possibly due to a networking or fencing
hardware failure or misconfiguration. As a result, some or all filesystem
operations may be paused throughout the cluster. In addition, filesystem
mounts and unmounts and disk imports and deports can not be performed.
Action. HP Clustered File System is unable to exclude servers that have
become unresponsive, or to verify the fencing of servers that were
previously fenced and have not yet been rebooted. Possibly the fencing
device is not responding to the fencing request or the Ethernet connection to
the FibreChannel switch has failed. Also check for other networking or SAN
hardware problems. The servers should be rebooted as soon as possible.
17006 This cluster takes control of SAN failure resolved.
Action. None. Alert 17005 is resolved.
ID Message and Corrective Action