HP StorageWorks Clustered Gateway 3.6.0 Windows Storage Server Edition Event Notification Guide (5697-7151, January 2008)

Chapter 3: Event Messages 32
13912 <server> unable to access imported disk <disk> resolved.
Action. None. Alert 13911 is resolved.
13913 Membership partition <partition> should be least <size>.
Action. The minimum size for a membership partition is 1GB. The specified
partition is too small and should be replaced. If three membership partitions
are configured, you can replace the partition while the cluster is online. (Use
the Replace feature on the Storage Settings tab of the Configure Cluster
window.) If only one membership partition is configured, add two more
partitions using the Add feature on the Storage Settings tab and then replace
the original partition.
13914 Membership partition size resolved.
Action. None. Alert 13913 is resolved.
13915 Membership partition <partition> corrupt and must be repaired as soon as
possible.
Action. Use the mx config mp repair command or the Repair button on the
Storage Settings tab of the Configure Cluster Window to repair the partition
while the cluster is online. If the cluster is offline, use the mx config mp
repair command or resilver the partition with the mprepair utility.
13916 Membership Partition <partition> corruption resolved.
Action. None. Alert 13915 is resolved.
ID Message and Corrective Action