HP StorageWorks Clustered Gateway 3.6.0 Windows Storage Server Edition Event Notification Guide (5697-7151, January 2008)

Chapter 3: Event Messages 11
4518 Probe failed: <monitor> monitor timeout failed.
The monitor probe failed on the specified server. The server may no longer
be suitable for the virtual host(s) associated with the monitor. If the virtual
host(s) were active on the affected server, they may have failed over to
another server. (Whether failover occurs is dependent on the configuration
of the monitor and the virtual host(s).)
Action. Verify that the monitor is configured correctly. Check the server and
the network interface associated with the virtual host(s) for problems.
4519 Monitor timeout resolved.
Action. None. Alert 4518 is resolved.
4520 Probe failed: <IP address> virtual host address has been unexpectedly
removed from interface <interface>.
The monitor probe failed on the specified server. Another attempt will be
made to activate the virtual host.
4521 Virtual host address has been restored.
Action. None. Alert 4520 is resolved.
4522 Probe failed: <IP address> virtual host address release failed.
The monitor probe failed on the specified server. Another attempt will be
made to activate the virtual host.
4523 Virtual host address release resolved.
Action. None. Alert 4522 is resolved.
4524 Probe failed: <IP address> Unsupported monitor type '<monitor>'.
The monitor probe failed on the specified server. The server may no longer
be suitable for the virtual host associated with the monitor. If the virtual host
was active on the affected server, it may have failed over to another server.
(Whether failover occurs is dependent on the configuration of the monitor
and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and
the network interface associated with the virtual host for problems.
4525 Unsupported monitor type resolved.
Action. None. Alert 4524 is resolved.
ID Message and Corrective Action