HP StorageWorks Clustered Gateway 3.6.0 Windows Storage Server Edition Event Notification Guide (5697-7151, January 2008)

Chapter 3: Event Messages 10
4512 Probe failed: <IP address> monitor probe failed.
The monitor probe failed on the specified server. The server may no longer
be suitable for the virtual host associated with the monitor. If the virtual host
was active on the affected server, it may have failed over to another server.
(Whether failover occurs is dependent on the configuration of the monitor
and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and
the network interface associated with the virtual host for problems.
4513 Monitor probe resolved.
Action. None. Alert 4512 is resolved.
4514 Probe failed: <monitor> monitor probe failed.
The monitor probe failed on the specified server. The server may no longer
be suitable for the virtual host(s) associated with the monitor. If the virtual
host(s) were active on the affected server, they may have failed over to
another server. (Whether failover occurs is dependent on the configuration
of the monitor and the virtual host(s).)
Action. Verify that the monitor is configured correctly. Check the server and
the network interface associated with the virtual host(s) for problems.
4515 Monitor probe resolved.
Action. None. Alert 4514 is resolved.
4516 Probe failed: <IP address> monitor process timeout.
The monitor probe failed on the specified server. The server may no longer
be suitable for the virtual host associated with the monitor. If the virtual host
was active on the affected server, it may have failed over to another server.
(Whether failover occurs is dependent on the configuration of the monitor
and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and
the network interface associated with the virtual host for problems.
4517 Monitor timeout resolved.
Action. None. Alert 4516 is resolved.
ID Message and Corrective Action