HP StorageWorks Clustered File System 3.6.1 Windows Storage Server Edition event notification guide (AG515 - 96011, August 2008)

Chapter 3: Event Messages 35
13935 FenceAgent: disabled status being reported on <IP_address>.
Fabric fencing is configured and there is an operational problem with
the specified FibreChannel switch.
Action. Check the switch for faulting or failed components such as GBICs
and/or faulting slots.
13936 FenceAgent: disabled status being reported on <IP_address> resolved.
Action. None. Alert 13935 is resolved.
17001 Singleton cluster unable to take control of SAN, because the cluster that
includes NN.NN.NN.NN currently controls the SAN. Possibly this server
has not been added to the cluster or has been deleted from the cluster, or
possibly a networking failure or misconfiguration has partitioned this server
from the servers that control the SAN.
Action. Check the cluster configuration and add the server if it is not
currently a member. Also check the network to ensure that the server can
communicate with the rest of the cluster.
17002 Singleton cluster takes control of SAN failure resolved.
Action. None. Alert 17001 is resolved.
17003 This cluster unable to take control of SAN, because another cluster that
includes NN.NN.NN.NN currently controls the SAN. Possibly a networking
failure or misconfiguration has partitioned these servers from the servers
that control the SAN, or possibly this cluster has been misconfigured to
share membership partitions with another cluster.
Action. Check the cluster configuration and add the server if it is not
currently a member. If your site has more than one cluster, use mprepair to
make sure that this server is using the correct set of membership partitions.
17004 This cluster takes control of SAN failure resolved.
Action. None. Alert 17003 is resolved.