HP StorageWorks Clustered File System 3.6.1 for Windows installation guide (AP809-96008, October 2009)
Chapter6:OtherProcedures 46
withthisconfiguration.However,youwillneedtosetuptheLUNsthat
willbeusedwithHPClusteredFileSystembeforeyoubegintheHP
ClusteredFileSysteminstallation.ForinformationabouttheLUNs
requiredforHPClusteredFileSystemoperations,see“11.CreateLUNs
fortheMembershipPartitionsand
ModifyPartitionTables”onpage18.
“New Server See Nothing” Mode
OnlythoseserversthathavebeenidentifiedbytheMAGNITUDEstorage
arrayareallowedtoseespecificallym appedLUNs.Thestoragearray
usestheWWIDoftheFCHostBusAdaptertomanagethismodeof
operation.
BeforeinstallingHPClusteredFileSystem,youwillneedtoperformthe
followingprocedure,whichensuresthattheLUNsareavailablewhen
youconfigure
HPClusteredFileSystem.
Completethefollowingsteps:
1. SetuptheLUNsthataregoingtobeusedbyHPClusteredFile
System.(See“11.CreateLUNsfortheMembershipPartitionsand
ModifyPartitionTables”onpage18.)
2. Whenbootingeachserver,pressCtrl‐QtoentertheQLogicSetup
Program.
3. Select
“ScanforFibreDevices”fromthemenu.
4. Pagethroughtheresultsuntilyouseethe
MAGNITUDEdevice.
5. Onthe
MAGNITUDEdevice,maptheLUNstotheWWIDs.
ExittheQLogicSetupProgram.Theserverwillrebootautomatically.