HP StorageWorks Clustered File System 3.6.1 for Windows installation guide (AP809-96008, October 2009)

Chapter3:InstallHPStorageWorksClusteredFileSystem 21
Partition Sizing
Itisimportanttoproperlysizethepartitionsthatwillbeusedfor
membershippartitions.(Theminimumsizeis1GB.)
12. Log Into iSCSI Targets (iSCSI Configurations
Only)
LogintoeachiSCSItargetviatheiSCSIinitiatorandsettheiSCSIInitiator
Properties.OntheLogOntoTargetdialog,besuretocheck
Automaticallyrestorethisconnectionwhenthesystemreboots.”
Youwillneedtocompletethissteponeachserver.
13. Run the mxcheck Utility
Beforeinstallingtheclustersoftware,itisimportanttoverifythatthe
serversconfigurationmeetstherequirementsforrunningHPClustered
FileSystem.YoucanusetheHPmxcheckutilitytodothis.
Theutilityperformsthefollowingchecksontheserver:
•Systemcheck:hardware,operatingsystemversion,servicepack
version,available
physicalmemory.
•Networkcheck:IPnetworkandinterfaceassignments,forwardand
reversehostnamelookup.
•Storagecheck:HostBusAdapters,drivers,andsettings.
Miscellaneouscheck:othercheckssuchasthenonpagedpoolsetting.
Torunmxcheck,ins e rtthe HPStorageWorksX5500NetworkStorage
GatewayforWindowsCDintotheCDdrive
orgotothedirectorywhere
youdownloadedtheproductandthendoubleclickthefilemxcheck.exe.
Outputfromtheutilityappearsonthescreenandisalsowrittentothe
ApplicationLogsectionoftheEventViewer .Werecommendthatyoufix
anyproblemsidentifiedbymxcheckbeforeyouinstall
HPClusteredFile
System.