Chapter 4: Other Procedures 42
with this configuration. However, you will need to set up the LUNs that
will be used with HP Clustered File System before you begin the HP
Clustered File System installation. For information about the LUNs
required for HP Clustered File System operations, see “12. Create LUNs
for the Membership Partitions and Modify Partition Tables” on page 20.
“New Server See Nothing” Mode
Only those servers that have been identified by the MAGNITUDE storage
array are allowed to see specifically mapped LUNs. The storage array
uses the WWID of the FC Host Bus Adapter to manage this mode of
operation.
Before installing HP Clustered File System, you will need to perform the
following procedure, which ensures that the LUNs are available when
you configure HP Clustered File System.
Complete the following steps:
1. Set up the LUNs that are going to be used by HP Clustered File
System. (See “12. Create LUNs for the Membership Partitions and
Modify Partition Tables” on page 20.)
2. When booting each server, press Ctrl-Q to enter the QLogic Setup
Program.
3. Select “Scan for Fibre Devices” from the menu.
4. Page through the results until you see the
MAGNITUDE device.
5. On the
MAGNITUDE device, map the LUNs to the WWIDs.
Exit the QLogic Setup Program. The server will reboot automatically.