Chapter 3: Setting Up HP StorageWorks Clustered File System 29
1. SAN Switches. Specify the hostnames or IP addresses of the
FibreChannel switches that are directly connected to the nodes in the
cluster. Click Add, and then specify the hostname or IP address of the
first FC switch. Repeat this procedure to specify the remaining FC
switches, including cascading switches. If you are using an MPIO
configuration, be sure to configure all of the switches.
2. SNMP Community String. The default SNMP community string for
HP Clustered File System is private. If you want to use a custom
community string, enter the appropriate value here. The SNMP
community string must be set to the same value on HP Clustered File
System and on the SAN switches configured above.
When you have completed the information, go to the Storage Settings tab.
Web Management-Based Fencing
When you select either iSCSI storage or FibreChannel storage with Web
management-based fencing, the SAN & Fencing tab will refresh and ask
you for configuration information. Enter the appropriate information for
the Remote Management Controller associated with the server that you
used to connect to the Management Console.
NOTE: Later in this procedure the complete cluster configuration will be
exported to the other servers that will be in the cluster. During the
export, HP Clustered File System will, where possible, use the
information that you specified on the SAN & Fencing tab to
configure Web management-based fencing on the other servers. If
a particular entry on the SAN & Fencing tab did not apply to all
servers, HP Clustered File System will ask for that information for
each of the other servers.