HP StorageWorks Clustered File System 3.6.0 Windows Storage Server Edition Installation Guide (418975-003, January 2008)

Appendix A: Configure the Cluster from the Command Line 54
The other webfencing options are:
--vendor <vendor>
The vendor for your remote management controller (dell, hp, ibm, or
ipmi).
[--bladeslot <slot>]
For IBM Blade Center only, the blade slot.
--mixedvendor yes|no
Whether the vendor and type settings apply to all servers.
[--rpassword <password>]
The password for the Remote Management Controller.
--ruser <user name>
The Remote Management Controller user name.
[--sharedlogin yes|no]
Whether the login account is shared by all servers.
--type reset|shutdown
When a server needs to be restricted from the SAN, HP Clustered File
System can either power-cycle the server or shut it down. Select the
method that you want to use (either reset or shutdown).
mx config snapshot add --method <type> [--options <method
options>]
Configure a snapshot method. The options are:
--method <type>
The supported types are hpeva and engenio.
[--options <method options>]
For hpeva, specify the following:
--hostname <hostname>
The hostname for the management appliance.
--username <username>
The user name required to access the management appliance.
--passwd <password>
The password required to access the management appliance.