HP StorageWorks Clustered File System 3.6.0 Windows Storage Server Edition Administration Guide (403103-005, January 2008)
Table Of Contents
- Contents
- HP Technical Support
- Quick Start Checklist
- Introduction to HP Clustered File System
- Cluster Administration
- Administrative Considerations and Restrictions
- Tested Configuration Limits
- Volume and Filesystem Limits
- User Authentication
- Start the Management Console
- Cluster Management Applications
- The HP CFS Management Console
- View Installed Software
- Start HP Clustered File System
- Stop HP Clustered File System
- Back Up and Restore the Cluster Configuration
- HP Clustered File System Network Port Numbers
- Configure Servers
- Configure Network Interfaces
- Configure the SAN
- Configure Dynamic Volumes
- Configure PSFS Filesystems
- Manage Disk Quotas
- Manage Hardware Snapshots
- Configure Security Features
- Configure Event Notifiers and View Events
- Overview
- Install and Configure the Microsoft SNMP Service
- Cluster Event Viewer
- Configure Event Notifier Services
- Select Events for a Notifier Service
- Configure the SNMP Notifier Service
- Configure the Email Notifier Service
- Configure the Script Notifier Service
- View Configurations from the Command Line
- Test Notifier Services
- Enable or Disable a Notifier Service
- Restore Notifier Event Settings to Default Values
- Import or Export the Notifier Event Settings
- Using Custom Notifier Scripts
- Cluster Operations on the Applications Tab
- Configure Virtual Hosts
- Configure Service Monitors
- Configure Device Monitors
- Advanced Monitor Topics
- SAN Maintenance
- Other Cluster Maintenance
- Management Console Icons
- Index

Chapter 19: SAN Maintenance 250
Export Configuration Changes
When you change the membership partition configuration with
mprepair, it updates the membership list on the local server. It also
updates the lists on the disks containing the membership partitions
specified in the local MP file.
After making changes with mprepair, you will need to export the
configuration to the other servers in the cluster. To do this, start HP
Clustered File System on the server where you ran mprepair and then
connect to the HP CFS Management Console. Select File > Configure to
display the Configure Cluster window and go to the Cluster Wide
Configuration tab. Select the other servers in the Address column and
then click Export.
mprepair Options
HP Clustered File System can operate with either one membership
partition or three membership partitions. To ensure that a membership
partition is always available, we recommend that you use three
membership partitions.
Display Membership Partitions. To display information about
membership partitions, type the following command:
mprepair --display_mplists
The output shows the local membership partition list on the server where
you are running mprepair. It then compares this list with the lists located
on the disks containing the membership partitions. The output also
includes the device database records for the disks containing the
membership partitions. Following is an example.
###################################################################
Local membership partition list:
-------------------------------------------------------------------
Membership partition list --
UID/Part:20:00:00:04:cf:13:33:12::0/1 Local Path:\\.\Global\psd1p1
Status:OK (active) Size:8001Kb
These membership partitions contain a membership partition list
which matches the local membership partition file list:
UID/Part:20:00:00:04:cf:13:33:12::0/1
###################################################################
Contents of UID/Part:20:00:00:04:cf:13:33:12::0/1 --