HP StorageWorks Clustered File System 3.1.1p1 Linux Edition Upgrade Guide (February 2006)
Chapter 2: “All-at-Once” Upgrades 5
11. If you saved any HP Clustered File System configuration files in step
3, compare the saved files with the new versions of the files that were
installed with HP Clustered File System 3.1. (The new versions were
installed in the directory /etc/opt/hpcfs.) You will need to migrate your
customized values from the old files to the new files as necessary.
12. Install the Management Console:
# rpm -i mxconsole-3.1.1p1-<xxxx>.i586.rpm
13. Install the CFS-Linux support RPM from the CFS-Linux product
location where you have downloaded the software.
# rpm -i mxfs-support-3.1.1p1-<xxxx>.x86_64.rpm
Then install CFS-Linux 3.1.1p1 from the product location where you
have downloaded the software.
# rpm -i mxfs-3.1.1p1-<xxxx>.x86_64.rpm
14. Install the CFS-Linux 3.1.1p1 update 1 rpm.
# rpm -Uhv pmxs-patch-3.1.1p1-0001 .x86_64.rpm
15. Start HP Clustered File System. Run the following command:
# /etc/init.d/pmxs start
16. Correct the permissions on the snap.conf and sssu files for EVA
snapshots. From the location where you uncompressed the upgrade
package, run fix_eva_snapshots.sh.
The upgrade is now complete.