HP StorageWorks Clustered File System 3.1.1 for Linux Installation Guide (May 2006)
3
2
Configuration Information
HP is continually expanding its supported hardware and operating
system configurations. For the latest information, check the QuickSpecs
for the HP Clustered File System on the HP web site:
http://www.hp.com.
Hardware Configuration Limits
The configuration limits for hardware used in a Clustered File System
configuration are as follows.
Hardware
Configuration Limit
Servers Two to 16 servers.
Network Interface Cards Up to four network interfaces per server
have been tested. Configurations with more
NICs are possible. Contact HP for
information on larger configurations..
FibreChannel Host Bus
Adapters
Four FC ports per server can be connected to
the cluster SAN. Other FC ports can be
connected to non-cluster SANs.
FibreChannel Switches
Two levels of cascading switches.
FibreChannel Storage
Subsystems
Up to 508 LUNs.