HP Clustered FileSystem3.6.1 for Windows release notes (T4422-96003, September 2008)
• Defect 19672. After the Configure Cluster GUI was opened, the “Starting
Configuration Utility” status popup also remained open.
• Defect 19659. A dynam ic volume was inaccessible after a cluster transition
occurred while the volume was being deported.
• Defect 19704. Some non-cached file extending writes could result in an
inconsistent internal state and cause a panic.
• Defect 19716. An invalid attempt to release a resource caused a kernel fault.
• Defect 19756. Alerts in HP Clustered File System 3.4 and 3.6 are incompatible;
however, during a rolling upgrade the alerts were logged on a ll nodes. Now,
3.4 alerts are logged only on nodes running 3.4 and 3.6 alerts are logged
only on nodes running 3.6.
• Defect 19801. The usage statements for the psfssuspend and psfsresume
commands indicated that a drive letter was required.
• Defect 20036. Offline membership partition operations did not work in certain
situations.
• Defect 20192. The HP Managem ent Console did not allow a 1GB LUN to be
used for a membership partition.
• Defect 20286. The mxds process terminated on a node, causing HP Clustered
File System to stop on that node .
• Defect 20321. TheSANPulseprocess terminated while a snapshot wasbeing
created.
• Defect 20500. The PSFS filesystem did not grant FILE_ADD_SUBDIRECTORY
access properly to privileged callers.
• Defect 20501. The PSFS filesystem did not check directory access correctly
during some rename operations.
• Defect 20811. The mxtrap.mib file prov ided with HP Clustered File System did
not
compile cleanly with the HP Systems Insight Manager (SIM).
• Defect 20968. The message event text for events 4512 and 4516 incorrectly
attempted to interpret a value as a system error number a nd the text contained
error information that was not appropriate for the event.
• D e f e c t 21111. U I c o m m a n d s r a n f o r e v e r i n t h e b a c k g r o u n d i f t h e c l u s t e r s e c r e t
was inadvertently changed while HP Clustered File System was running. The
commands
will now complete in error if the cluster secret is changed while the
product is running.
• Defect 21191. The SCLD process failed when a particular timeout occurred.
FS O
ption for Windows fixes
The following FS Op tion for Windows issues have been corrected in this release:
• Def
ect 19283. A race condition caused m onitor_agent to fail.
• Defect 19769. A resource lea k existed in the monitor probe.
HP Clustered File S ystem 3.6 .1 f or Windows
5