HP ProLiant Storage Server Release Notes (5697-7451, June 2008)

Additional app lications and utilities
Description
When Subsystem is clicked in Storage Manager for SAN, the system stops
responding and displays the message MMC has detected an error in a
snap-in and will unload it. Thisbehaviorisseenonlywhenanyofthe
MSA subsystem volumes are being expanded.
Workaround
Use the Array C
onguration Utility (ACU) to access the MSA subsystem when
volumes are be
ing expanded.
Issue:
NfsSvr logs a
nerrorintheeventlog
Description
On systems with Windows Storage Server 2003 R2, the event log may contain an
error stating that Ser ver for NFS failed to initialize on a non-existent drive letter.
For example:
Event Type: ErrorEventSource: NfsSvrEvent Category:
NoneEvent ID: 1066Description: Server for NFS failed to
initialize on volume with drive letter F:
Workaround
This error does not affect the performance of NFS. The issue will be resolved in a
later HP ProLiant Storage Server release.
Issue:
Internet Explorer closes un expectedly
Descript
ion
When runni
ng Java-based applications or Java-enabled content, Internet Explorer
unexpect
edly closes.
Workaround
1. In Internet Explorer, on the Tools menu, select Internet Options.
2. Click the Advanced tab and then check the Enable third-party browser
extensions check box.
3. Restart the storage server.
NOTE:
After succ essfully running a Java application, you can disable this setting.
Issue:
ProLiant Management Server agents incorrectly identify the storage server product name and t ype
Description
The agents from ProLiant Support P ack versions 7.7 and 7.8 incorrectly read the
conguration information for all P roLia nt Storage Servers. This prevents the System
Management Home Page and other management applications, such as Systems
Insight Man ager, from correctly identifying the system.
Workaround Upgrade to ProLiant Support Pack version 7.90 or l ater.
System installation and recovery process
This section describes issues related to installing the operating system on a storage server or performing
the recovery process.
System installation and recovery process
Iss
ue:
After restoring the system with the System Installation and Recovery DVD, the data drive may be
see
n by Windows as a foreign disk
Description
If the data drive was a dynamic disk prior to performing a system recovery, the
disk may be designated as a foreign disk by Windows after the recovery. This
issue is seen in the Disk Management MMC snap-in.
Workaround
Open the Disk M anagement snap-in. Right-click on the foreign disk and select
Import disk.
Storage Server release notes