HP DC04 SAN Director Switch Hardware Reference Guide

4. Verify that all the IP address information is correct by entering the ipaddrshow command
and comparing the results with the IP information recorded in the config-miscinfo.txt
file.
rsl8-st03-dcx-1:admin> ipaddrshow
SWITCH
Ethernet IP Address: 10.32.50.12
Ethernet Subnetmask: 255.55.0.0
Fibre Channel IP Address: 1.2.3.4
Fibre Channel Subnetmask: 255.255.255.0
CP0
Ethernet IP Address: 10.32.50.10
Ethernet Subnetmask: 255.55.0.0
HostName : cp0
Gateway Address: 10.32.40.1
CP1
Ethernet IP Address: 10.32.50.11
Ethernet Subnetmask: 255.55.0.0
HostName : cp1
Gateway Address: 10.32.40.1
Backplane IP address of CP0 : 10.0.0.5
Backplane IP address of CP1 : 10.0.0.6
rsl8-st03-dcx-1:admin>rsl8-st03-dcx-1:admin>
Reconnecting to the network and the fabric
NOTE: The ports and cables used in trunking groups must meet specific requirements. For a list
of these requirements, see the Fabric OS Administrator's Guides.
See the cable routing information that was recorded in Table 19 (page 95) for the following steps:
1. Connect the CP blades to the LAN:
a. Insert the appropriate Ethernet cables into each Ethernet port.
b. Connect the other ends to an Ethernet 10/100 Base-T LAN, if not already connected.
IMPORTANT: The DC04 SAN Director can be accessed by remote connection using
any of the available management tools, such as Telnet or Web Tools. Ensure that the
DC04 SAN Director is not modified using other connections during the rest of this
procedure.
2. Reconnect the transceivers and cables to the port blades.
a. Position one of the transceivers so that the key is oriented correctly to the port and insert
the transceiver into the port until it is firmly seated and the latching mechanism clicks.
b. Select the cable that corresponds to the port and position it so that the key (the ridge on
one side of the cable connector) is aligned with the slot in the transceiver; then, insert the
cable into the transceiver until the latching mechanism clicks.
c. Repeat step 2a and step 2b for the remaining ports.
TIP: Do not route cables in front of the air exhaust vent (located on the upper port side
of the chassis).
d. Organize the cables as required.
Replacing the DC04 SAN Director chassis 93