HP DC04 SAN Director Switch Hardware Reference Guide
Determining whether or not to replace a CP blade
The following events might indicate that a CP blade is faulty:
• The status LED on the CP blade is amber, or the power LED is not lit.
• The CP blade does not respond to Telnet commands, or the serial console is not available.
• The slotShow command does not show that the CP blade is enabled.
• The haShow command indicates an error.
• The clock is inaccurate, or the CP blade does not boot up or shut down properly.
• Any of the following messages is displayed in the error log:
Slot unknown message relating to a CP slot◦
◦ CP blade errors or I
2
C timeouts
◦ FRU: FRU_FAULTY messages for a CP blade
◦ Configuration loader messages or Sys PCI config messages
◦ Generic system driver messages (FABSYS)
◦ Platform system driver messages (Platform)
◦ EM messages that indicate a problem with a CP blade
◦ Function fail messages for the CP master
For more information about error messages, see the Fabric OS Message Reference.
70 Replacing DC04 SAN Director FRUs